Heavy metal wastewater treatment system
- 型式:DPM
特徴
● Selectable treatment way according to the type of heavy metal wastewater.
● High contralability with touch panel, and easily view operation state.
● Simple data logger system.
仕様
Model | DP-25N | DP-50N | DPM-50N | DPM-100N |
Operation method | Semiautomatic※1 | Fully automatic | ||
Processing capacity | 25 L/time | 50 L/time | 100 L/time | |
Processing time | 1~2 hr/time | 1~2.5 hr/time | ||
Processing method | Oxidation, Deoidization, Cohesion, Prussian blue method, Neutralizaion, Filtration (paper filter), Activated charcoal adsorption, Chelate adsorption | Oxidation, Deoidization, Coagulative precipitation, Filtration (sand), Activated charcoal adsorption, Chelate adsorption, Deionization (option) | ||
Treatment target |
Common metals, Cyanogen, Cyanide complex, Hexavalent chromium, Mercury, Organic matter, Acid / alkali, Disinfectant(※2) |
Common metals, Cyanogen, Cyanide complex, Hexavalent chromium, Mercury, Organic matter, Various complexes, Wastewater (pH2~12) |
||
Capacity | Heavy metal 1000 mg/L, Cyanogen 500 mg/L, Mercury 50 mg/L, Acid / alkali pH2~12 | Heavy metal 1000 mg/L, Cyanogen 500 mg/L, Mercury 50 mg/L | ||
External Dimension (W×D×H mm) |
650×650×1445 | 800×700×1445 | 1800×1250×1800 |
※1 Fully automatic can be selected by option.
※2 Wastewater pH range is 2~12.